Product Description

Battery Charge & Discharge Battery Test System

Product Info

Unit USD
Minorder 1
Supplyability 30 Set/Sets per Month
Port shenzhen
Certification ISO,CE
Place DongGuang,China
Packaging Each set protected by resin fiber and PP film, then put into Strong wooden case with operation manual and vedio inside.

Product Detail

Battery Charge & Discharge Battery Test System

 

Technical Specification
 

1. Application and Function

1.1 Application: mainly used for circle life testing and quality control of li-ion battery and VRLA Working battery in production line or in lab.

1.2 Support battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charge retention capability testing, 

charge and discharge efficiency testing, over charge or over discharge rate affordability testing.


 

2. Working Environment and Technical Parameters

2.1 Power supply: AC300V±15%

2.2 Control Mode:The CC mode and CV mode are double closed loop structure, each channel is independently controlled

2.3 Energy Feedback:Full power energy feedback, the feedback energy is given priority to the local load, and the excess energy is feedback to the grid



Standards:
 

Model Name HD-E7001-800V200A
 
Channel Basic Parameters
Max. Voltage 800V
Max. Current 200A
Main Channel Number 1
ADC Bits 24 Bit
Control Mode The CC mode and CV mode are double closed loop structure, each channel is independently controlled
Energy Feedback Full power energy feedback, the feedback energy is given priority to the local load, and the excess energy is feedback to the grid
 
Grid Side Parameters
Voltage Range 400Vac/480Vac ±10%
Frequency Range 50Hz/60Hz ±5Hz
Max. Power 173.9kW
Power Factor >0.99
THDi <5%
Wiring 3W+PE
Isolation Type Low Frequency Isolation
 
Channel Voltage Parameters
Charge Voltage Range 0~800V
Discharge Voltage Range 3V~800V (Add accessories to discharge to 0V )
Voltage Accuracy ±0.05% F.S
Voltage Resolution 1mV
Voltage Ripple ±0.5% F.S
 
Channel Current Parameters
Single CH Current Range -200A~200A
Parallel CH Current Range(Optional) /
Current Accuracy ±0.05% F.S
Current Resolution 1mA
Min. Cut-off Current ±0.2% F.S (Can be adjusted down according to demand)
 
Channel Power Parameters
Single CH Max. Power 160kW
Parallel CH Max. Power /
Power Accuracy ±0.1% F.S
Power Resolution 1W
 
Charge and Discharge Parameters & Functions
Current Response Time ≤10ms(10%~90%)
Charge and Discharge Switching Time ≤20ms(-90%~+90%)
Min. Pulse Width 100ms
Charge Mode CC, CV, CC-CV, CP, Current Ramp, Pulse, etc.
Discharge Mode CC, CC-CV, CP, CR, Current Ramp, Pulse, DCIR, etc.
Cut-off/Jump Condition Voltage, Current, Time, Temperature, Capacity, Energy, -ΔV, Expression Function, etc.
Loop Test Range 1~65535 Times
Editable number of steps 254 Steps
Loop Nesting Support 3 Layers
Programming Features There are multiple exits for each step, with "goto" function, which can jump arbitrarily
Simulation File Can import the working condition file (DBC format), edit the working condition file according to the communication protocol
Simulation lines limit 1 Million Rows
Simulation Switching time 100ms
Grid Side Protection Overvoltage Protection, Overcurrent Protection, Phase Loss Protection, Overheat Protection, Overload Protection, Short Circuit Protection, Communication Interruption Protection, Emergency Stop Protection, etc.
Battery Side Protection Overvoltage Protection, Overcurrent Protection, Power Failure Protection, Reverse Connection Protection, Communication Heartbeat Protection, Overcapacity Protection, Sampling Line Drop Protection, etc.
Efficiency (Full Load) >92%
 
PC Software Parameters & Functions
Communication Type TCP/IP Protocol
Functional Test Items Operating Condition Simulation, Capacity, Internal Resistance, Cycle Life, Charge/Discharge Characteristics, Pulse Charge-Discharge Characteristics, Charge Retention Capability, Charge-Discharge Efficiency, Overcharge/Overdischarge Tolerance, Cell Temperature /Voltage Characteristics, Consistency Assessment , etc.
Software Step Operation Cut/Paste Step, Forced Step Jump, Condition Jump, Loop Test, etc.
Min. Time Interval 10ms
Min. Voltage Interval 0.1mV
Min. Current Interval 0.1mA
Data protection Power-Down Data Protection
Offline Test
Safety protection conditions can be set, setting parameters include: Voltage Upper Limit, Voltage Lower Limit, Current Upper Limit, Current Lower Limit, Delay Time, etc.
Software/System Interface Database, MES System, LIMS System, etc.
Peripheral   Communication Ports RS485, RS232, CAN2.0A, CAN2.0B, CANFD, Ethernet, etc.
Devices BMS, Auxiliary Voltage, Auxiliary Temperature, Environmental Test Box, Water Cooler, Insulation Monitoring, Adjustable Power Supply, Equalization Equipment, etc.
 
Basic Parameters
Size W*D*H: 2000*1070*1980(mm)
Weight ≈ 1500kg
Protection Level IP20
Cooling Type Air-Cooled
Noise <75dB
Storage Temperature -30℃~70℃
Operating Temperature -10℃~45℃
Humidity <85% (No Condensation)
Altitude ≤2000m
 
Optional Accessories
Computer i5, 8G, 1T, Integrated Graphics, 21-inch, Windows10 Chinese Operating System, Mouse (Customizable)
DC Cable Room temperature RV, Silicone Cord, etc. (Customizable)
Fixture Polymer Clamps, Alligator Clips, OT Terminals, Toggle Clamps, etc.
Battery Rack Designed according to the battery size and the number of channels, the laminate is insulated, and the bottom is equipped with casters (Customizable)
Auxiliary Channel Designed according to the maximum voltage, temperature range, thermocouple type, and number of channels
Discharge to 0V Module Designed according to the number of channels
Charge and Discharge Different Port Module Designed according to the maximum voltage, maximum Current, and the number of channels
Negative Voltage Discharge Module Designed according to the maximum voltage, maximum current , and the number of channels
Power Distribution Box (DC, AC) Designed according to the maximum voltage, maximum current, and the number of channels
Power Transformer Designed according to the maximum voltage  and the maximum power

Products Categorys